Fire engines - the new generation of rescue vehicles
Fire engines - the new generation of rescue vehicles

Ansinh 1.500

"CHỮA CÁC ĐÁM CHÁY ABCD- KHÔNG CẦN NỔ MÁY"

Car Fire & Rescue 1500 Ansinh made ​​on the basis of ISO 7884: 2008, the patent for the Company's shares
MOST GREEN SECURITY Vietnam and the United States by the end.

 

 
I. STRUCTURE

1500 + vehicles equipped Ansinh:
  - Water Tank: Capacity: 3.5 m3 - Working pressure: 7-10bar.
  - CO2 Rating: 6 average. Total capacity: 230kg of liquid CO2. Pressure: 70-80bar.
  - Medical Oxygen: 2 comments. Total capacity: 12m3 99.95% oxygen. Pressure: 150bar
  - 8 "dual coil taps" AS-CV2 20-50m long, with 5 levels CO2/nuoc/bot spray,
  - 2 "Double hose reel" AS-CV3 100m long, with 5 levels CO2/nuoc/bot/oxy spray,
  - Versatile gun on the roof with 6 types of steam fountains of fire suit,
  - 2 Ansinh 1.500/30 wheeled extinguishers for fighting in narrow alleys and far away.
The equipment on the car for 3 soldiers adequate guidance 20-30 volunteers joined fire and rescue safety performance under the motto: "Fire the people".

II. PRINCIPLE OF OPERATION FIRE TRUCK NEW GENERATION:

 
CÔNG NGHỆ PHUN CAO ÁP
CHỈ TẠO RA TIA NƯỚC NHỎ
KHÔNG KHÍ VẪN CÒN NGUYÊN
AN SINH PHUN HÓA HƠI 
TẠO RA KHỐI TÍCH GẤP 1.500 LẦN
ĐUỔI HẾT KHÔNG KHÍ

When sprayed on the fire, mist collector for water vapor, thereby rapidly lowering the combustion temperature and oxygen concentration is diluted to below the limit of fire fighting force to stop the reaction. When added with 0.3% AS-B foam to create water "mixture slightly nuoc/CO2/bot" somewhat colliding objects will condense into water / foam and add effects to cover the surface asphyxiation, wetting, surface cooling, to stop the fighting and start the fire.

Synthesis of the elements above, 1 liter of water into 1,500 liters of water vapor. It is also the basis for naming the fire trucks Ansinh 1500.
 The process of extinguishing the fire trucks Ansinh 1500 took place with the full effect of the heat-of-cultural-both on the surface and in the volume. That is: Lower levels of oxygen in the fire, vapor concentrations diluted fire-foam wetting surfaces, fire, choking, cooling, insulation and fire suppression response. Thanks to fire off quick, minimizing damage caused by water. Water vapor also absorbs heat and toxic smoke to reduce the risk involved fire, facilitating the escape, reducing environmental pollution.

 Due to the intense make vapor blast 1,500 times greater than the initial amount of water covering fire Space. The intensity of the spray 4-5 times stronger and away from water line characteristics (just hit the ground) under the same conditions and pressure tube similar obstacles.

Experiments showed that 1,500 vehicles Ansinh versatile extinguish the fire of a solid, liquid, gas and electricity.
Special: As recommended in the Standard AS, BS, Vietnam, Chapter 3, Section 3. Standard 10.2.5 of NFPA 58, Chapter 11, Section 11.1.6 NFPA 59 are clearly stated: "Normally Gas fires Shall not be extinguished until the source of the burning gas has been shut off": The gas fire is often impossible extinguished until the gas valve ignition sources. However, thanks to the mass spraying area, 1,500 vehicles were tested Ansinh extinguish it civil LPG cylinder valve without power.

+ When fighting high-rise garage basement Ansinh 1,500 just spray down, not necessarily forcing the soldier to reach the fire and explosive gasoline fumes are dangerous.

+ Use a spray gun Ansinh CO2 dry cleaning electrical fire did not cause electric shock, fire the office, documents, money, computer, damaged property does not get wet.

 + There oxygen fire protection and emergency equipment to people with smoke inhalation.
 1,500 + Car Ansinh system automation equipment for fire fighting vehicle itself.
 + There is a powerful device and remote fire to destroy the enemy.


III. SPECIFICATIONS:
 
The parameters Car Fire & Rescue
Ansinh 1500
A) FUNCTIONAL FIGHTING:

a) Quality Fire:

  - The water in the tank,
  - CO2 can be adjusted from 0-10bar pressure.
  - Foaming AS-B

b) Fire fighting equipment:

- Guns roof: With 6 instead of fast jets, including:

1. Chemical spray hose D50 x L500 straight round
2. Chemical spray hose D60 x L500 straight round
3. Spread flat hose spray evaporation D50 x L300
4. Gassing spray faucet spread round D50 x L400
5. Nozzle ring of water vapor can protect fire fighters
6. A spray of water vapor Lang
7. 02 of D65 traditional steering hose to add water to the tank receives, directly or sprinkler system coupling on fire inside a building or facility.

+ "Double roll" AS-CV2 versatile gun mount AS-SN

+ "Double roll" AS-CV3 versatile gun mount AS-SL
      When customers need to add oxygen tube D5
    
  - Fire rescue trucks choking Ansinh 1.500/30,

  - Pumps and sprinkler water supply (transmitted from the gearbox)

c) promote water efficiency and the actual fighting:

  - Number of times the push of CO2 tank with 3,500 liters of water reserves in the car,

  - The sample gas fire (area 4.5 m2/dam - TCVN7435: 2003) vehicles can simultaneously extinguished,

  - Jacuzzi Time 1 foam fire extinguish petrol 4.5 m2,

  - Fire building: Use the zipper roll up hose from outside the fire downstairs to reach the top.

B) FUNCTIONS AND RESCUE:

- 99.99% medical oxygen cylinders
- The oxygen taken against asphyxia,
- Wind stone cutting and welding equipment, synergy pliers, hammers, crowbars ...
- Ice song (for the given function stroller up and down)
- Medical equipment rescue,
- Light whistle priority,
- Speakers commander,

C) specialized functions:

- Fire fighting equipment for fire trucks themselves

 
3.500lit water spray steam into 5,000,000 liters.

230kg CO2 liquid spray into 115,000 liters of CO2

200lit - phase ratio of 0.3%.

Range sputtering / vapor flow cross section (round / flat):

Away from 40-60m / Round D3m
Away from 40-70m / Round D5M
Away from 30-40m / Flat, 10m wide
Away from 30-40m / Round D6m
Away from 40-60m / Round D1m
Away from 40-60m / Round D1m
Away from 20-30m / Round D1m

Length / spray distance range:
    
4 roll length 20m / 25m sputtering,
4 rolls 50m / 20m sputtering.
2 rolls 30m long distance 100m/Phun

2 car. Each vehicle contains 5kg of CO2, 930 liters of oxygen and 30 liters of water.

1 pcs

-----------------

4 times, a total of 14m3 of water

10 gas fire extinguishing a total area of ​​45m2 in 30giay

No more than 25 seconds

Elevation of 500m to 100m or ordered upon request.
    ---------------
2 comments containing oxygen 12m3
10 sets
01
01
01
01
01

01 sets
01, spraying distance 30-50m
 

Note:

+ Specifications and equipment on the vehicle is adjusted according to customer requirements.
+ CO2 reserves enough to push 4 times / 3,500 liter tank, with a total capacity of 14m3 water will turn into steam to fire 20.000m3. When the CO2, 1,500 vehicles Ansinh still use pumps to fire continuously engaged in high technology.
+ Oxygen and breath taking special fire protection and smoke inhalation aid to compliance with the provisions of the health sector.
+ There are fire equipment required to destroy or suppress enemy riots.
+ Specification of the facility by car manufacturer announced in the attached Appendix.
     
 IV. RELEVANCE:

 1,500 + Vehicles Ansinh meet universal motto Fire, Rescue, destroy the enemy, suppress riots protect people. Suitable for city, residential, river ports, sea ports, industrial parks, substations, factories, etc ... to reduce the risk of fire spread quickly threatening people and property.
 + Vehicle promote efficient storage for fire and gasoline outlets, gas pump allocating ammunition arsenal, airports, car garage, electrical equipment, fires in closed rooms, floors fire any floor and basement of the super high-rise, mines, tunnels crossing the mountains, there are many chemical storage tanks, toxic smoke from the fire more ...
 + Fire process can keep documents, computers, money, power cabinets ... not wet down.

V. HOW TO USE:

+ In the cabin there are three professional soldiers used loudspeakers guide for 20-30 people volunteered to pull hose, open the valve at the firearms can fire rescue participate safely and effectively. Guns on the roof by the soldiers but also can charge entrusted to volunteers according to state fire commanders professional soldiers in the area near or far from fire trucks.

  Specifically:
  + When fire occurs:
- If there is smoke inhalation: Open the oxygen valve and wear take their breath before cure.
- On average CO2 valve,
- Use a spray gun on the roof directly into the fire,
- Pull the hose reel Roller approach and extinguishing the fire in the following way:

 + Use Ansinh versatile firearms:

- Cover the gun will spray faucet spread from 1.5 to 2.0 m2 to close fire fighting (Figure 1)
 - Remove the cap gun hose to spray away from fire or high 20-30m (Figure 2)
- Open the gas valve - Water valve: air spray fire-prone repair water damage property.
- Open the valve 2: Turn water into steam curing properties at fire water damage.

 
Figure 1. To cap gun to spray spread round Figure 2. Open the lid to spray away
Figure 3. Installation of fire hose to large flat Figure 4. "Roll with the three" have oxygen to breathe


USE ONE HAND GUN AN EASY LIVING

+ Use Ansinh gun on the roof:

D50 spray gun straight, wide 3-4m away from 40-50m.


D60 steam spray gun a 5-6m, 50-60m away.


SECURITY spray guns spread flat type, distance 30-40m 8-10m wide.


65 Using traditional wheel CO2 foam, water and fire water receive


USED ​​CAR LOT OF Ansinh 1,500 extinguish FIRE MORE


Ansinh 1500 FIGHTING EQUIPMENT TROLLEY Ansinh 1.500/30
FIGHTING FOR RESEARCH AND SMALL interrupt DEEP IN THE ALLEY

VI. Things USE NOTICE:

Chemical vapor +: Adjust water valve and gas flow so that the white mist like cotton.
Fire + chemical stores, fuel, pump stations, shops: Bring oxygen masks against toxic fumes, spray guns spread on the car combined with the dual hose reel and spray foam AS-B water vapor to quickly put shut down, avoid fire spread.
+ Use more foam AS-B phase maximum 0.3% when fighting fires as solid flooring, bedding. Especially for fabrics, wool, bags, blankets etc. ... AS-B foam to reduce the smoldering fire, non-toxic and pollution.
  + Do not use CO2 fire cure the alkali metals, alkaline earth, coke, fertilizer, because the injection of CO2 into the fire will produce toxic carbon monoxide has recently increased fire danger.
+ Do not use CO2 fire fighting in empty places, strong winds because of low efficiency.
+ After Fire: Reload water, CO2, O2, foam AS-B in the regulation.
+ Check the water level: Look for the measure during the high water level in the pressure tank.
+ Testing Methodology and maintenance of high-pressure bottle:
- Check the amount of CO2 in the bottle: Popular weight is used, if the amount of CO2 reduction compared to the initial average gas leak, not fully loaded.
- Testing of O2: Watch pressure gauge, load complement to the regulations.
- Every 3 years the pressure vessel inspection on the vehicle.

 

Car Ansinh 1500 4 TYPE FIRE extinguish solid, liquid or gaseous, ELECTRIC

Vehicle was Ansinh 1500 Vietnam Registry Agency Certificate Verification 0,149,846 KA, Da Nang City Police registration certificate dated 04.24.2013 No. 012 281.
In particular, do not have cars Ansinh 1500 steering hose couplings, the firearm Ansinh softly during fire without firing up the machine very easy to use and supported with technical obstacles.

AN SINH GREEN SCIENCE & TECHNOLOGY JOINT STOCK COMPANY
Other products

mai hien di dong da nang

 

mái hiên di động đà nẵng

 

mái hiên di động tại đà nẵng

 

mai hien di dong tai da nang